Lucene search

K
TendaAc9 Firmware15.03.06.42 multi

16 matches found

CVE
CVE
added 2024/02/26 10:15 p.m.4228 views

CVE-2024-25751

A Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the fromSetSysTime function.

9.8CVSS7.9AI score0.04571EPSS
CVE
CVE
added 2022/02/11 7:15 p.m.81 views

CVE-2020-26728

A vulnerability was discovered in Tenda AC9 v3.0 V15.03.06.42_multi and Tenda AC9 V1.0 V15.03.05.19(6318)_CN which allows for remote code execution via shell metacharacters in the guestuser field to the __fastcall function with a POST request.

9.8CVSS9.7AI score0.03387EPSS
CVE
CVE
added 2022/05/24 12:15 p.m.63 views

CVE-2021-42659

There is a buffer overflow vulnerability in the Web server httpd of the router in Tenda router devices such as Tenda AC9 V1.0 V15.03.02.19(6318) and Tenda AC9 V3.0 V15.03.06.42_multi. When setting the virtual service, the httpd program will crash and exit when the super-long list parameter occurs.

6.5CVSS6.8AI score0.00205EPSS
CVE
CVE
added 2024/02/05 9:15 p.m.46 views

CVE-2024-24543

Buffer Overflow vulnerability in the function setSchedWifi in Tenda AC9 v.3.0, firmware version v.15.03.06.42_multi allows a remote attacker to cause a denial of service or run arbitrary code via crafted overflow data.

9.8CVSS9.5AI score0.01107EPSS
CVE
CVE
added 2025/05/02 3:15 p.m.41 views

CVE-2025-44877

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via the usbname parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

9.8CVSS8AI score0.01067EPSS
CVE
CVE
added 2025/05/02 3:15 p.m.40 views

CVE-2025-44872

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via the deviceName parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

9.8CVSS8AI score0.01067EPSS
CVE
CVE
added 2023/08/07 7:15 p.m.39 views

CVE-2023-38930

Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.

9.8CVSS9.6AI score0.00121EPSS
CVE
CVE
added 2023/08/07 7:15 p.m.39 views

CVE-2023-38936

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.

9.8CVSS9.6AI score0.00334EPSS
CVE
CVE
added 2023/08/07 7:15 p.m.39 views

CVE-2023-38937

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function.

9.8CVSS9.6AI score0.00121EPSS
CVE
CVE
added 2023/08/30 1:15 p.m.39 views

CVE-2023-41560

Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg.

9.8CVSS9.6AI score0.00121EPSS
CVE
CVE
added 2023/08/30 1:15 p.m.37 views

CVE-2023-41562

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet.

9.8CVSS9.7AI score0.00121EPSS
CVE
CVE
added 2023/08/07 7:15 p.m.36 views

CVE-2023-38933

Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.

9.8CVSS9.6AI score0.00121EPSS
CVE
CVE
added 2023/08/30 1:15 p.m.36 views

CVE-2023-41563

Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo.

9.8CVSS9.7AI score0.00121EPSS
CVE
CVE
added 2023/08/30 1:15 p.m.35 views

CVE-2023-41561

Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg.

9.8CVSS9.7AI score0.00121EPSS
CVE
CVE
added 2023/08/30 1:15 p.m.31 views

CVE-2023-41559

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting.

9.8CVSS9.7AI score0.00121EPSS
CVE
CVE
added 2023/08/07 7:15 p.m.29 views

CVE-2023-38935

Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function.

9.8CVSS9.6AI score0.00098EPSS